{"id":3793,"date":"2022-10-21T12:46:13","date_gmt":"2022-10-21T10:46:13","guid":{"rendered":"https:\/\/staging.mediaire.ai\/?p=3793"},"modified":"2025-09-03T09:10:54","modified_gmt":"2025-09-03T07:10:54","slug":"ai-assistant-in-the-mri-based-diagnostics-of-small-intracranial-aneurysms","status":"publish","type":"post","link":"https:\/\/mediaire.ai\/en\/ai-assistant-in-the-mri-based-diagnostics-of-small-intracranial-aneurysms\/","title":{"rendered":"AI-Assistant in the MRI-based Diagnostics of Small Intracranial Aneurysms"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"3793\" class=\"elementor elementor-3793\" data-elementor-post-type=\"post\">\n\t\t\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-4f80ddb3 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"4f80ddb3\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-306b3d44\" data-id=\"306b3d44\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-c77e4d0 elementor-widget elementor-widget-heading\" data-id=\"c77e4d0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Presented at<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0d710b2 elementor-widget elementor-widget-text-editor\" data-id=\"0d710b2\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><\/p>\n<p>Swiss Congress of Radiology (2022)<\/p>\n<p><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d7cc196 elementor-widget-divider--view-line elementor-widget elementor-widget-divider\" data-id=\"d7cc196\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"divider.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-divider\">\n\t\t\t<span class=\"elementor-divider-separator\">\n\t\t\t\t\t\t<\/span>\n\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-bdcb955 elementor-widget elementor-widget-heading\" data-id=\"bdcb955\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Authors<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6e9e13a elementor-widget elementor-widget-text-editor\" data-id=\"6e9e13a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><\/p>\n<p>Klail T., Radojewski P.<\/p>\n<p><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d7217bf elementor-widget-divider--view-line elementor-widget elementor-widget-divider\" data-id=\"d7217bf\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"divider.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-divider\">\n\t\t\t<span class=\"elementor-divider-separator\">\n\t\t\t\t\t\t<\/span>\n\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-91d3115 elementor-widget elementor-widget-heading\" data-id=\"91d3115\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Abstract<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-14708ef3 elementor-widget elementor-widget-text-editor\" data-id=\"14708ef3\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><strong>Purpose<\/strong><\/p>\n<p>Small incidental aneurysms represent a clinical challenge, since it is often difficult to distinguish them other structures (e.g. infundibulary branch) using standard field strengths (1.5\/3T MRI). The diagnostic gold standard in form of digital subtraction angiography (DSA) is associated with radiation exposure and potential co-morbidities. On the other hand, tools based on artificial intelligence (AI) are becoming more accessible to support the radiologist in the assessment of MRI images. How such assistants perform in the most challenging cases remains unclear. Our first goal was to compare the evaluation of standard (1.5\/3T MRI) images performed by the AI-assistant vs. radiological assessment and then compare these findings with a consensus reading performed with 7T-MRI.<\/p>\n<p><strong>Materials &amp; Methods<\/strong><\/p>\n<p>Fifty patients with a suspected small-sized aneurysm in the standard 1.5\/3T MRI examination (n=9\/41) received 7T MRI examination for clarification based on the decision of the aneurysm-board. The 1.5\/3T TOF-images were analyzed with the mdbrain software (mediaire, CE-certified and authorized for routine diagnostic use) for aneurysm detection. The sensitivity, specificity and accuracy of the software vs. radiological report on the 1.5\/3T MRI were compared. Subsequently a comparison with the 7T MRI evaluation done by the consensus and the aneurysm-board was performed.<\/p>\n<p><strong>Results<\/strong><\/p>\n<p>Twenty-one (42%) patients had an aneurysm confirmed by the 7T MRI (mean age = 53 years; m\/f = 17\/33). The sensitivity for aneurysm detection was higher in radiological assessment than in AI-based assessment (86% vs. 62%). The specificity was lower in radiological assessment than in AI (14% vs. 86%). Half of the evaluations done by physicians were false negative in this highly selected population. The accuracy was higher for the AI-based than for the radiological assessment (76% vs. 44%).<\/p>\n<p><strong>Discussion<\/strong><\/p>\n<p>The use of AI in the diagnosis of small aneurysms as a support tool for physicians is promising, as it provides valuable support in image evaluation.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-274adc6 elementor-widget elementor-widget-image\" data-id=\"274adc6\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"800\" height=\"458\" src=\"https:\/\/mediaire.ai\/wp-content\/uploads\/2022\/10\/14-external-Aneurysm-validation-7T-InselSpital-Bern-Kleil-1024x586.png\" class=\"attachment-large size-large wp-image-17930\" alt=\"\" srcset=\"https:\/\/mediaire.ai\/wp-content\/uploads\/2022\/10\/14-external-Aneurysm-validation-7T-InselSpital-Bern-Kleil-1024x586.png 1024w, https:\/\/mediaire.ai\/wp-content\/uploads\/2022\/10\/14-external-Aneurysm-validation-7T-InselSpital-Bern-Kleil-300x172.png 300w, https:\/\/mediaire.ai\/wp-content\/uploads\/2022\/10\/14-external-Aneurysm-validation-7T-InselSpital-Bern-Kleil-768x440.png 768w, https:\/\/mediaire.ai\/wp-content\/uploads\/2022\/10\/14-external-Aneurysm-validation-7T-InselSpital-Bern-Kleil-18x10.png 18w, https:\/\/mediaire.ai\/wp-content\/uploads\/2022\/10\/14-external-Aneurysm-validation-7T-InselSpital-Bern-Kleil.png 1495w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/>\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">Performance of mdbrain for detection of small incisional aneurysms &lt;3mm on 1.5T\/3T data compared to consensus of experienced neuroradiologists - Validation with 7T MRI - With slightly lower sensitivity (62% vs. 86%) significantly higher specificity of mdbrain (86% vs. 14%).<\/figcaption>\n\t\t\t\t\t\t\t\t\t\t<\/figure>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>Small incidental aneurysms represent a clinical challenge, since it is often difficult to distinguish them other structures (e.g. infundibulary branch) using standard field strengths (1.5\/3T MRI). The diagnostic gold standard in form of digital subtraction angiography (DSA) is associated with radiation exposure and potential co-morbidities.<\/p>","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[14],"tags":[],"class_list":["post-3793","post","type-post","status-publish","format-standard","hentry","category-publications"],"acf":[],"_links":{"self":[{"href":"https:\/\/mediaire.ai\/en\/wp-json\/wp\/v2\/posts\/3793","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/mediaire.ai\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/mediaire.ai\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/mediaire.ai\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/mediaire.ai\/en\/wp-json\/wp\/v2\/comments?post=3793"}],"version-history":[{"count":3,"href":"https:\/\/mediaire.ai\/en\/wp-json\/wp\/v2\/posts\/3793\/revisions"}],"predecessor-version":[{"id":21638,"href":"https:\/\/mediaire.ai\/en\/wp-json\/wp\/v2\/posts\/3793\/revisions\/21638"}],"wp:attachment":[{"href":"https:\/\/mediaire.ai\/en\/wp-json\/wp\/v2\/media?parent=3793"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/mediaire.ai\/en\/wp-json\/wp\/v2\/categories?post=3793"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/mediaire.ai\/en\/wp-json\/wp\/v2\/tags?post=3793"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}